Chapter 1 Brief Introduction
1. Introduction
Air Intake System is an electrical automated control product for poultry house, which is developed by Qingdao Xingyi Electronic Equipment Co., Ltd. and which has integrated the production experience in poultry breeding industry in China.
The air intake system can not only enhance efficiency, reduce labor intensity but also can adjust air intake angle and volume of entering air.Working with fans it can guarantee there is enough oxygen and fresh air inside the house, thus offering an optimum growing environment. With least engergy consumption, the system helps achieve best effects. It is an indipensable equipment for modern and scale raising farms. 
2. Safety Notices
1) Before use, please read through this manual carefully. 
2) Before turning on the power, please make reliable grounding of the earthing lines.
3) Do not drag power lines with force. 
4) For repair or maintenance, do cut off power.
5) Installation and maintenance workers must be qualified after training. 

Chapter 2 Operation Instructions
1 Installation of Air Intake System
1.1 Installation of Air Intake
1.1.1 Opening Air Intake Holes
According to ventilation requirements of the house, make square holes in the end and side walls in accordance to the design dimensions (as shown in fig 2-1 and 2-2). 
 
Fig. 2-1  Dimensions of end wall holes
 
Fig. 2-1 Dimensions of side wall holes
 
The height of the holes is determined by the height of the wall and other conditions on site. Normally it should be no less than 600mm. 

1.1.2  Installation of air intakes
First put the air intake(JF/S-001)into the preset hole and adjust the four sides to ensure flatness and vertical profile diagonal to the hole bottom platform, as shown in fig. 2-2. After that, drill holes in the outer frame of the air intake and through the hole drill a hole into the wall behind. Insert a plastic expansion pipe(JF/S-101)into the hole and tighten a self-tapping screw(JF/S-102)in it. There must be at least 3 sets of such holes in the longer side of the air intake and one in the shorter side. 
After installation of the air intake, fasten the ejection mechanism(JF/S-002)with expansion bolts(JF/S-103).
 
 
 
Fig. 2-2 Installation of air intake
 
No.Description and ModelRemarks
1Air IntakeJF/S-001
2Plastic expansion pipeJF/S-101
3Self-tapping screwJF/S-102
4Ejection mechanismJF/S-002
5Expansion bolt M6×60JF/S-103
 
 
1.1.3  Installation of air intake open system
As shown in figure 2-1 and  2-2, first fix the drive mechanism(JF/S-003)on the wall with expansion bolts(JF/S-104). Then anchor pulley ass'y (JF/S-004), pulley ass'y (JF/S-007) and install bracket (JF/S-005) on the wall with expansion bolts(JF/S-103)or expansion bolts(JF/S-104).
Fix the puller board (JF/S-006) on the plate of the air intake(JF/S-001) with self-tapping screws (JF/S-107), bolts and lock nuts (JF/S-108) .
Thread the main wire rope(JF/S-104)through pulley assemblies(JF/S-004, JF/S-007) and anchor one end around the rolling shaft of the drive mechanism. Cut the other end at proper point, thread it through the loop of the counterweight stick(JF/S-008) and fasten it with a wire rope clip(JF/S-105).
Open the loop of the nylon pully(JF/S-106), hang it on the install bracket and connect the pulling ropes(JF/S-104)in sequence as shown in the figure.
 

No.
Description and modelRemarks
1Drive mechanismJF/S-003
2Expansion bolt M8×80JF/S-104
 
3Wire rope φ3mmJF/S-104
 
4Pulley ass'yJF/S-004
5Wire rope clip M5JF/S-105
 
6Install bracketJF/S-005
7Expansion bolt M6×60JF/S-103
 
8Nylong pulley 1-7/8"JF/S-106
 
No.Description and modelRemarks
9Puller boardJF/S-006
10Self-tapping screw ST6×25JF/S-107
 
11Bolt M6×12 and lock nut M6JF/S-108
 
12Air intake JF/S-001
13Pulley ass'yJF/S-007
14Counterweight stick(6kg)JF/S-008
15Ejection mechanismJF/S-002

 

 
1.1.4  Adjustment of baffle
By adjusting the branch wire ropes, ensure the opening angle of the air intakes are consistent. Do not open the air intakes to full opening angle so as to prevent flocks from harms of direct hit of winds.
To finish installation, ensure all air intakes close when the drive motor reach the minimum travel distance and they open when the motor reach the max. Travel distance.
 
1.2 Installation of light trap ass'y
After installation and commisioning of the system, seal the crevices between the air intakes and the wall with cement or PU foaming agent from outside the house to ensure air tightness before installing light trap assemlies. 
 
Fig. 2-3  Installation of light trap
No.Description and ModelRemarks
1Light TrapJF/S-009
2BracketJF/S-010
 
3Self-tapping screw ST4.8×16JF/S-109
 
4Expansion bolt M6×60JF/S-103
 
Set the positions of the two brackets (inner distance 1266mm)  according to figure 2-3. Align the upper straight side of the bracket with the wall for the hole. Drill a hole on either side of the wall for expansion bolt and insert the bolt(JF/S-103)into the hole. Insert the light trap(JF/S-009)37mm into the wall hole and slip the bracket(JF/S-010)onto the bolt. Adjust the light trap so that it is flat and straight and then tighten the nuts. At last mount the bracket above the light trap to secure the trap and seal the crevices with cement or glass sealing glue.
2  Inspection before use
a)  Insert the plug of the power line into the 4-pole socket (with earthing socket).
b)  Ground th earthing line reliably before power on.
3  How to use
3.1  Startup of the air intake system
a)  After grounding the earthing line, insert the power plug. 
b)  Turn on the main switch of the 24V power box and then the main controller. Press the "Page Down" key on the controller panel on the startup page to find peripheral equipment management on page 3. Find item"air intake" under this menu. If there is a tick in the bracket before the item air intake, this means it is in the auto control status-the on/off and opening size will be controlled by the system automatically. Otherwise, it means the air intake is in the manual control status.
c)  To use manual control to adjust the air intake, press the enter key on the item air intake to remove the tick in the bracket. At this time, the air intake is in manual control status. After that, return to page 3 and find the "air intake size" option under menu "relay management". You can adjust the opening size to wide position by "air intake to wide" and close the air intake gradually by "air intake to narrow". When you are using these two functions, pay attention to the status of the air intake all the time and press enter key to stop the running if anything odd happens. 
3.2  Notices:
a)  When using the manual winch, be sure to make inching press on the key and pay attention to the status of the air intake all the time and press enter key to stop the running if anything odd happens.
b)  Often check if there is blockage or stagnation along the wire rope and transmission parts. If any plz put the switch to "stop" and make adjustment.
3.3  Operation
a)  In normal conditions, plz set the air intake in the status of auto control so as to let the climate controller supervise all the actions of the switches.
b)  In the cold winter, the air intakes are not needed considering environment requirements. During this season, make sure to keep the air intake closed. 
 
 

Chapter 3 Technical Instructions
1 Operating Environment Conditions
To make most out of the excelletn performance of the air intake system and achieve best control results, we have the following requirements on the operating environment of the system:
    a)  Environment Temperature:-20~50ºC
b)  Environment Humidity:10-90%RH
c)  Altitude:<2000m
d) No flammable or explosive gas around.
    e)  Power supply:three-phase five-wire(three phase lines, zero line and protective earth line)380/220VAC ±10%,50Hz.
 
2. Technical specifications
a) The system can change the volume of the intaken air and the intaking direction.
b) It can acquire smooth air flow by reduce the number of the opening air intakes and increase their opening angle. 
3. Working principle
The air intake system controls the air intake volume and angle into the house to achieve an optimum raising environment according to the supervision by the climate controller over the in-house environment. 
The main principle of the system is:the drive mechanism pulls the wire ropes to close the air intakes. Upon release of the wire ropes, the intakes will open by self weights. According to different seasons, air temperatures and live ventilation requirements, the  system can adjust the opening angle and the number of the opening air intakes to implement precise control over the volume of the intaken air. 
Because on a raising farm, the raising density is high and metabolization of chicks active, the raisers must provide a good living environment for the flocks. For this environment, the amonia density cannot exceed 20g/cbm, H2S density no higher than 5g/cbm and CO2 density no higher than 0.24%. In winter, it's easy for broilers to be afflicted with ascites, escherichia coli and other diseases because of inadequate ventilation and high density of harmful gases. To keep the air inside the chick house fresh, the workers should open doors, windows, air inlets/outlets or turn on exhaust fans for proper ventilation. The purposes for ventilation include:  remove extra heat and vapor inside the house;  remove the dirty air inside the house to improve the air quality;  remove the dust inside the house.
The main measures for chick house ventilation are through opening/closing doors, windows and ventilation holes. During winter and spring when the air temperature is low, chilling air must be prevented to hit the chicks directly. The raisers decide the times of opening/closing doors/windows, their opening angles and lengths of opening/closing time according to chick density, chick age, air pressure and density of harmful gases, thus keeping the air fresh and moderate temperature inside the house at the same time. For fully-closed chick house, the raisers can turn on exhaust fans for ventilation.
To judge if the ventilation is proper or not, the standard is: the air is not pungent, smelly and will not cause tears. The raisers can also measure the density of harmful gases with measuring instruments. 
Ventilation and heat preservation is contradicting. This contradiction is especially outstanding in cold autumn and winter seasons. Whether you can reach a good balance on this contradiction decides the result of production. Do not let the inside temperature drop dramatically because of ventilation, for which the young chicks will catch cold. At the same time do not ignore ventilation because of heat preservation, which will sure influence the air quality and induce different chick diseases. Recommendation: increase the inside temperature (usually by 1 - 2 ºC) before exercising ventilation; when the temperature drop to the needed value, stop ventilation immediately. Try to exercise ventilation around the noon when it is sunny. The length of time for a single ventilation opertion cannot be long but you can increase ventilation times. 
During summer when it is hot, the main purpose for ventilation is to reduce the inside temperature and alleviate heat stress of the birds. Regardless of positive or negative pressure ventilation, the ideal air flow is from east to west or from north to south. At night and in the early morning, the raisers still need to increase ventilation even if the birds do not pant during the time. If the outside temperature is already higher than the inside around noon, the raisers should reduce ventilation. 
The key points to control of broiler house environment:  when you feel light uncomfort upon entering the house, ventilation is needed  replace the padding materials and remove manure in time to reduce generation of harmful gases.  pay attention not to let the inside temperature drop dramatically because of ventilation. At night and in the early morning during summer ventilation should be increased. If the outside temperature becomes higher than the inside, stop ventilation. 


Chapter 4 Maintenance Instructions
1 Maintenance and Repair
The air intake system only needs little maintenance or repair work. However, periodical checkup is necessary to eliminate potential problems. Before maintenance or repaire, remember to cut off the power, otherwise personal injury might occur. 
2  Maintenance
a) Wash the air intakes after each batch of flocks..
b) Check all fasteners and tighten the loose ones.
c) Lubricate the pulleys.
3  Troubleshooting
 
No. PhenomenaReasonsSolutions
1The motor does not work. 1.The power is not pluged.
2.The fuse burns out. 
3.The motor becomes defective. 
1. Plugs the power. 
2. Replace the fuse. 
3. Repair the motor. 
2Air intakes cannot close fully or open to max. Angle or have different opening angles.1. The puller rope is not in place. 
2. Something is wrong with the ejection mechanism . 
3. The transmission parts block. 
1. Adjust the length of the puller rope. 
2. Adjust the ejection mechanism and add lubricant. 
3. Check out the block spots. 
 
Table 4-1
Qingdao Xingyi Electronic Equipment Co., Ltd. And Qingdao Free Trade Zone EI Electronic Co., Ltd(www.eifhj.cn)are affiliated companies of the 41st Institute of China Electronics Technology Group Corporation. They focus on research development and manufacture of EI incubation equipment and accessories. EI electronics is the largest research and production base, the biggest dealer and the strongest enterprise of the modern incubation equipment in China. The 41st Institute of China Electronics Technology Group Corporation (www.ei41.com)is the only research institute covering the whole range of electronic measurement instruments in China. With the technical advantages, the institute has developed four industrial categories in integrated breeding system, fire fighting system, and tobacco machinery control system and telecommunication equipment. The company has built two production bases both in Bengbu, Anhui and Qingdao, Shandong:

Bengbu base was founded in 1984 with the yearly output reaching 10, 000 Box-type incubation units and 6, 000 breeding units. In 2010, EI incubation and breeding equipment production park convering 410mu started to be constructed

Qingdao base was founded in 1995 with a capacity of 8, 500 units, which include tunnel incubator, air-circulation incubator, vaccine incubator, poultry house automatic machines, etc.

Send your message to this manufacturer

  • Inquiry about Ei-Ft/X Air Intake System

Other Products From This Manufacturer