Product Specifications
| Prod Model: |
RAY-GC122 |
| Markets: |
North America,South America,Eastern Europe,Southeast Asia,Africa,Oceania,Mid East,Eastern Asia,Western Europe |
| Linear Range: |
10e6 |
| Gas: |
Gas-Chromatograph |
| Type: |
Gas-Chromatograph |
Product Description
Specifications:
1) Trace toxics analysis, monitoring and research in environmental protection, atmosphere and water source pollution;
2) Biochemistry, clinic application, pathology and toxicology research;
3) Microorganism analysis and research in food ferment, and microelements analysis in beverage;
4) Intermediate and finished product analysis in Chinese and western medicine materials;
5) Crude oil composition analysis and control in petroleum processing, petrochemical industry, petroleum geological industry, and geological prospecting research;
6) Component research and production control in organic chemistry and organic synthesis;
7) Analysis and research in sanitary quarantine, labor protection, and hazard detection;
8) Monitoring, control and research in cutting-edge science and military technologies.
Features
Newly designed, high performance HRGC
Double FID detectors in the basic type with wide accessory options such as GCl22-TCD thermal conductivity detector, GCl22-ECD electron capture detector, GCl22-NPD nitrogen and phosphorous detector, GCl22-FPD flame photometric detector, converter, gas sample inlet valve, etc.
In the basic type, the instrument has dual packed columns, double samplers and dual gas path system structure, which can effectively restrain baseline fluctuation and drift in real time, suitable for temperature programming analysis. The instrument can work with three types of detectors at the same time. With different detector combination in different application, the instrument can support detectors working in either cascade or paralleled connection.
The instrument in the basic type is equipped with completed capillary analysis system and independent capillary split sampler, which includes diaphragm cleaning, split flow and auxiliary gas adjustment. It supports capillary split / split less sampler, cold on-column sampler, and 0.53mm large diameter capillary column direct sampler. It's suitable for all kinds of capillary column of various diagrams, speculations, and lengths, and made of glass or flexible silicon glass.
The instrument supports following injection methods:
Packed column: On-column sample injection, instantaneous vaporizing sample injection, gas sample injection Capillary column: Split injection, split less injection, large diameter column direct injection
Newly developed computer aided temperature control system. It can manage the temperature control of six path heating areas at the same time, including column, ion chamber, thermal conductivity detector, capillary column sampler, packed column sampler auxiliary and standby, with high precision (less than ± 0.1º C) and wide range (up to 400º C), and temperature overload and deviation is less than 2º C or even lower.
The column has five-phase programmed temperature control, and the highest heating rate is up to 40º C/min.
The system has such functions as switch-off protection, temperature limit setup, temperature scanning, rapid automatic cooling, I. E. Back opening door, and etc.
Open-end computer system can apply RS-232 interface and N-2000 chromatogram workstation to achieve single path communication control and data processing.
Performance Indicators:
Temperature control range: 7º C-400º C of room temperature (increment by 1º C)
Temperature control objects: Column, ion chamber, thermal conductivity, sampler A, sample B, auxiliary (standby)
Temperature programming phase: Five
Temperature programming rate: 0.1º C-40º C/min(increment by 0.1º C)
Flame Ionization Detector (FID)
Sensitivity: M≤ 1× 10-11g/s(sample: C16)
Optimal test result: M≤ 5× 10-12g/s
Baseline noise: ≤ 5× 10-14A
Baseline drift: ≤ 6× 10-13A/h
Linear range: ≥ 10E6
Raylabel Ltd., founded in 2005.
We are a professional manufactures laboratory equipments, medical apparatus and school furniture which have a very powerful R&D team and now becoming the professional Lab equipments total solution provider in this field. Our company has obtained ISO9001: 2000 and ISO13485: 2003 certificate of quality management system registration approval. Raylabel products show extremely long life span and stability in the function.
All the sale engineers from Raylabel Ltd., have strong professional experience. Some of them have been more than 15 years. Our company operates its business with the management philosophy of "customer first, service forever". We are proud of the supporting with our perfect quality of products and timely service systems. And we sell our products to all parts of the country and overseas.
Based on the global instrument market awareness and marketing strategies, Raylabel products are increasingly becoming excellent OEM supplier and partner, We will based in China to provide more advanced and high quality products and better service.
Our goal is to be an international lab equipments and school furniture supplier worthy of trust, and we are dedicated to benefiting our customers by minimizing their cost with reasonable prices and maximizing their profits with trouble free products.
Choose "Raylabel", Choose a Most Valuable Business Partner!