Integrated Tube Type Ultrasonic Flow Meter (A+E 80FD)
Product Specifications
| Prod Model: |
A+E 80FD |
| Markets: |
North America,South America,Eastern Europe,Southeast Asia,Africa,Oceania,Mid East,Eastern Asia,Western Europe |
| Power Supply: |
DC or AC Optional |
| Max Flow Velocity: |
10 M/S |
| Communication: |
Modbus, FUJI |
| Signal Output: |
Isolated RS485 |
| Body Material: |
Carbon Steel |
| Accuracy: |
?à0.6-1% |
| Main Application: |
Corrosive Liquid/Gas |
| Sensor: |
Tube/Flange |
| Type: |
Ultrasonic Flow Meter |
| Measuring Media: |
Liquid |
| Measuring Principle: |
Acoustics |
| Size: |
Dn 15-300 (1/2'' to 12'') |
| Application: |
Water Treatment |
Product Description
Integrated Tube Type Ultrasonic Flow Meter (A+E 80FD)

Specifications:
Measurement Accuracy: Better than 1%,
Repeatability: Better than 0.2%
Measurement Period: 500ms (2 times per second, and 128 groups of data is collected during each period)
Working Power Supply: Isolated DC8~36V or AC85~264V is optional
Max Flow Velocity: 10m/s (flow resolution ratio 0.001m/s)
Display: 2*10 backlit display (Chinese and English are optional)
Operation: 4 magnetic keys window mode operation
Signal Input:
--3-way 4-29mA analog input, accuracy 0.1%, and pressure, liquid level, temperature signal can be inputted.
--2-way three-wire system PT100 platinum resistor
Signal Output:
--1-way isolated RS485 output
--1-way isolated OCT (The pulse width of 6~1000ms is programmable and the default value is 200ms)
--1-way relay output (The pulse width is 200ms)
--1-way 4-20mA output (active/passive output is optional)
--1-way Bi-directional Serial Universal Peripheral Interface that can be connected to multiple external devices throughcascade (such as mass data storage module)
Communication Protocol: MODBUS protocol
Other Functions:
--Automatically memorize the positive/negative/net accumulative flow of the past 512 days, 128 months, or past 10 years.
--Automatically memorize the past 30 times of power-on time, power-off time and flow, and realize the automatic or manual flow replenishment, which can be read via MODBUS Protocol.
--Software updating can be realized through code files sent through E-mail.
Power-off Protection: Datas can be stored without loss after 100, 000 hours' power off.
Protection Grade: IP68
Electrical Interface: M16*1.5| Letter | Parameters | Options |
| A | Mainframe type: | F1 Split wall-mounted type F2 Split anti-explosion type F3 Split panel-mounting type F4 Split transmitting type |
Y Integrated type (local 4 magnetic keys cab be used to set parameters) W water meter (battery powered, the users can browse the windows via magnetic keys) |
M1 Module type (local 4 keys cab be used to set parameters) M2 Module type (The users can browse the windows via local single key.) |
| S1 economical type ((local 4 magnetic keys cab be used to set parameters) |
| B | Working power supply: | A AC (85-264VAC) B Battery (3.6V lithium battery) D DC (24V/8-36VDC) |
| C | Thermal function | N (N/A) Y (Yes) |
| D | Sensor type | B1 Standard S1 type B2 Standard M1 type B3 Standard L1 type B4 High-temperature S1H type B5 High-temperature M1H type |
C1 Standard Plug-in type C2 Cement Plug-in type C3 Water meter plug-in type |
G1 Standard Sectional type (flange connection) G2 Sanitary Sectional type (loose connection) |
| E | Measurement tube diameter | DN(mm)_____ |
| F | Pipeline material | 0 Carbon steel 1 Stainless steel 2 Cast iron 3 Fiberglass 4 PVC 5 Cement |
| G | Nominal Pressure | _____MPa |
| H | Flow accumulative unit | M stere L liter |
| Minimum reading (water meter) | 1 (m 3 ) 0.1 (0.1m 3 ) 0.01 (0.01m 3 ) 0.001 (L) 0.0001 (0.1L) |
| I | Thermal accumulative unit | K Kc (Kilocalorie) G Gj B BTU (Applicable at abroad) |
| J | Signal output: | N No output A 4-20mA F Frequency output R Pulse output 4 RS485 output |
| K | Signal input: | N No output 1 1-way 4-20mA input 2 2-way 4-20mA input 3 3-way 4-20mA input |
| L | Single cable length | ____meters (split sectional sensor has single four-core cable, and the other sensors have two twin-core cables) |
Shanghai AEAD Technology Co., Ltd is a cooperation of Chinese and German technique which mainly performs in R&D, production and sales.
AEAD Technology was first founded in 2009 in Jiangsu, and established Shanghai Branch in May 18th, 2014. The new Shanghai factory would complete in DEC 2014, located in the Free Trade Zone. Before the business started in 2009, the General Manager Mr. R. H. Liu and Technical Director Mr. S. P. Zong had dedicated in instrumentation for more than 20 years. After 5 years development and achieving good reputation in domestic market, we become a leading manufacture in East China. Now we believe we are ready to overseas users.
The company adopts advanced production line from Germany, and the main products include A+E series products for exporting and A+D products for domestic sales in pressure, temperature, flow, level, calibration and valve which can cater for the needs from domestic and foreign markets. Products are organized and sold under fully dedicated divisions, each staffed with an experienced and highly trained team of dedicated technical sales, applications engineering and customer service support personnel. Products are applied to water treatment, petrochemical, chemicals, machinery, pharmacy, food, mine, metallurgy, etc.
AEAD Technology adheres to the development strategy of Internationalization, Technicalization, Industrialization, which can realize the high-end extension of the products from domestic market to international market. The value chain turns from providing single product to system solution, and the operation expands from linear-oriented to a comprehensive modern enterprise operation including merger and capital operation.
The company has already passed the ISO9001 Quality Management System Certification, ISO14001 Environmental System Certification, and Occupation Health Safety Management System Certification (OHSAS18000).
Other Products From This Manufacturer