Categories
| Supplier: | Promise Technology Co., Ltd. |
|---|---|
| Price: | US $ 450-800/Piece |
| Min Order: | 1/Piece |
| Quantity:: | |
| Trade Terms: | FOB,CIF,DAT |
|
|
| Prod Model: | PRO-M7 |
|---|---|
| Markets: | North America,South America,Eastern Europe,Southeast Asia,Africa,Oceania,Mid East,Eastern Asia,Western Europe |
| LCD Size: | 7" TFT Display |
| Patient Records: | Display/ Store/ Playback/ Delete |
| Function: | St Segment Analysis; Pacemaker Detection |
| Storage: | Large Data Storage Capacity with Memory Card |
| ECG Lead Method: | I. II.III. AVR.Avl.Avf.V; I.II.III |
| ECG Gain: | 2.5/ 5.0/ 10/ 20 Mm/Mv. |
| ECG Lead Mode: | 3/5 Leads |
| Measurement Method: | Oscillometry |
| Pulse Rate Measure And Alarm Range: | 20-250bpm |
| Net Weight: | 2.15kg |
| Classification: | Physiological Functions of Diagnosis and Monitoring Equipment |
| Type: | Patient/Fetal/Maternal Monitor |
| Certification: | ISO13485 |
Technical Specification | ECG | Lead Mode: 3/5 leads | |||
| Lead Method: I. II.III. AVR.AVL.AVF.V; I.II.III | |||||
| Gain: 2.5/ 5.0/ 10/ 20 mm/mV. | |||||
| Sweep speed: 12.5/ 25/ 50 mm/s; | |||||
| 0-100% | Measure range: Adult: 15-300bpm Neonatal/ Pediatric :15-350bpm | ||||
| Accuracy : ±1% | |||||
| Resolution: 1bpm | |||||
| Respiration | Method: Impedance between RA-LL | ||||
| Gain: ×0.25/ 0.50/ 1/ 2/ 4 | |||||
| Respiration Rate: | Measurement Range: Adult: 0-120BrPM; Neonatal/ Pediatric: 0- 150BrPM | ||||
| Resolution: 1BrPM | |||||
| Accuracy: 0 - 6 BrPM (unspecified) ; 7-150 BrPM ; ±2BrPM | |||||
| NIBP | Measurement method : Oscillometry | ||||
| Measure Mode: Manual, Auto, STAT, Measure interval | |||||
| Auto mode: 1,2,3,4,,4,10,15,30, 60,90,120,180,240,480 min | |||||
| Pulse rate range : 40-240bpm | |||||
| Measure and Alarm Range | Adult Mode | SYS 40-280mmHg | |||
| DIA10- 220mm Hg | |||||
| MEAN20-240mmHg | |||||
| Pediatric Mode | SYS 40-220mm Hg | ||||
| DIA10- 160mm Hg | |||||
| MEAN20-170mmHg | |||||
| Neonatal Mode | SYS 40-135mm Hg | ||||
| DIA10- 100mm Hg | |||||
| MEAN20-110mmHg | |||||
| Resolution :1mm Hg | |||||
| Accuracy: Maximum mean error : ±5mm Hg | |||||
| Maximum standard deviation: 8mm Hg | |||||
| Overpressure Protection | Adult :300 mmHg | ||||
| Pediatric :240 mmHg | |||||
| Neonatal : 150 mmHg | |||||
| SP02 | Measurement range: 0-100% | ||||
| Resolution : 1% | |||||
| Accuracy: 70% -100%; ±2% <69% : unspecified | |||||
| Pulse Rate | Measure and alarm Range: 20-250bpm | ||||
| Resolution: 1bpm | |||||
| Accuracy: ±3bm | |||||
| Recorder (Option) | Paper Width: 48mm | ||||
| Speed : 25/ 50 mm/s | |||||
| Wave channels : 3 channels | |||||
ETCO2 (Option) | Measurement range: 0%-13% | ||||
| Resolution: 1 mmHg | |||||
| Accuracy: 2mm Hg <5.0% CO2 (at ATPS) | |||||
| Respiration rate : 3- 150 bpm | |||||
| Battery | 2200 mAh: 14.8 V rechargeable battery; Operating time: more than 2H working capacity; Max charging time: less than 4H; | ||||
| Power Supply | AC :100V - 240V, 50Hz- 60Hz | ||||
| Packing information | Net weight: 2.15KG Gross weight: 5.0KG Carton size: 360*260*310 mm | ||||