Categories
| Supplier: | Kingsine Electric Automation Co., Ltd. |
|---|---|
| Price: | Negotiable/Piece |
| Min Order: | 1/Set |
| Quantity:: | |
| Trade Terms: | FOB |
|
|
| Prod Model: | K3066I |
|---|---|
| Markets: | North America,South America,Eastern Europe,Southeast Asia,Africa,Oceania,Mid East,Eastern Asia,Western Europe |
| Voltage generators | ||
|
Setting Range |
7-phase AC (L-N) | 7 x 0 ... 300 V |
| 2-phase AC (L-L) | 2 x 0 ... 600 V | |
| Power | 7-phase AC (L-N) | 7 x 110VA, at 0 ... 300 V |
| 2-phase AC (L-L) | 2 x 220VA, at 0 ... 600 V | |
| Accuracy |
< 0.07% reading + 0.03% range guaranteed at 0 ... 300 V < 0.02% reading + 0.01% range typical at 0-300V |
|
| Resolution | 1mV | |
| Current generators | ||
|
Setting Range |
6-phase AC (L-N) | 6 x 0 ... 30 A |
| 3-phase AC (2L-N) | 3 x 0 ... 60 A (Group A II B) | |
| 1-phase AC (3L-N) | 1 x 0 ... 180 A | |
| Power | 6-phase AC (L-N) | 6x 450VA , at 0 ... 30A |
| 3-phase AC (2L-N) | 3x 520VA, at 0 ... 60A (Group A II B) | |
| 1-phase AC (3L-N) | 1 x 1000 VA, at 0 ... 180A (Max. ) | |
| Accuracy |
< 0.07% reading + 0.06% range guaranteed at 0-30A < 0.02% reading + 0.02% range typical at 0-30A |
|
| Resolution | 1mA | |
| Generators, general | ||
| Frequency | Range | 0 ... 1000 Hz |
| Accuracy / drift |
Error < 0.001Hz at 10 ... 65Hz, Error < 0.01Hz at 65Hz...450Hz Error < 0.02Hz at 450Hz...1000Hz |
|
| Resolution | 0.001Hz | |
| Phase | Range | - 360° ... +360° |
| Accuracy / drift | Error < 0.2 ° | |
| Resolution | 0.1° | |
| Timer | Range | Infinite |
| Accuracy / drift | Error< 0.1ms | |
| DC generators | ||
| Voltage ranges | 0 ... 300V/180W | |
| Current ranges | 0 ... 20A/300W | |
| Accuracy |
< 0.07% reading + 0.03% range guaranteed at 0-300V < 0.04% reading + 0.02% range typical at 0-300V |
|
|
< 0.14% reading + 0.06% range guaranteed at 0-20A < 0.05% reading + 0.02% range typical at 0-20A |
||
| Resolution | 1mA; 1 mV | |
| Aux DC Supply | ||
| Range | 0...300V/150W | |
| Binary inputs | ||
| Number | 8 pairs | |
| Compatible Voltage | 10V ... 250V DC | |
| Binary outputs | ||
| Number | 4 Pairs | |
| Capacity | 250V/3A AC/DC | |
| Synchronization | ||
| Synchronization mode | GPS | |
| Harmonic | ||
| Harmonic overlap times | 2 ... 20 times | |
| Power supply | ||
| Nominal input voltage | 220VAC± 20% | |
| Power | 1000VA | |
| Nominal frequency | 47Hz… . 65Hz | |
| Environmental conditions | ||
| Operation temperature | -5° C ... 55 ° C | |
| Storage temperature | -20° C ... 75 ° C | |
| Humidity range | 5% ... 90 %, non-condensing | |
| Weight | 20 KG | |
| Dimensions | 460(D)× 140 (W)× 360 (H) mm | |
| PC connection | RJ45, | |
| Model | Channels | AC Outputs |
| K3063i / K3063Li | 10 output channels | 6*30A/3*40A/4*300V |
| K3030i / K3030Li | 7 output channels | 3*30A/4*300V |
| K3066 | 13 output channels | 6*20A/3*40A/7*130V |
| K3063 | 10 output channels | 6*20A/3*40A/4*130V |
| K3040 | 7 output channels | 3*40A/4*130V |
| K3030 | 7 output channels | 3*30A/4*130V |
| Items | IEEE(R) No. |
| Synchronization relay | |
| Fault transplay | |
| GPS Synchronization | |
| Overcurrent relays | 50/76 |
| Inverse time overcurrent relays | 51 |
| Undercurrent relays | 37 |
| Ground fault relays | 50 |
| Directional overcurrent relays | 67 |
| Directional ground fault relays | 67N |
| Overvoltage relays | 59 |
| Undervoltage relays | 27 |
| Directional voltage relays | 91 |
| Directional power relays | 32 |
| Power factor relays | 55 |
| Differential protection (differential circuits) | 87 |
| Distance protection equipment (phase by phase) | 21 |
| Negative sequence overcurrent relays | 46N |
| Motor overload protection | 51/86 |
| Automatic reclosing devices | 79 |
| Tripping relays | 94 |
| Voltage regulating relays | |
| Overimpedance relays, Z> | |
| Underimpedance relays, Z | |
| Time-delay relays |