Categories
Price: | Negotiable/Piece |
---|---|
Trade Terms: | FOB,CFR,CIF |
Min Order: | 1/Piece |
Pay Type: | L/C,T/T,Paypal,Money Gram,Western Union |
H2F load cells are available for manifold accurate measurement in the capacities 1t to 50t. Alloy steel,potted with adhesive inside,oil-proof,waterproof and anti-corrosion,suitable for all kinds of environments. Spoke type,easy installation,suitable for electronic truck scales,hopper scales and other electronic weighing devices. Safe and anti-explosive product,can be used in atrocious environment and hazardous areas. | Important Features Capacities:1t to 50t. High accuracy. Alloy steel construction. |
Capacity | t | 15/20/30/50 | 5/10 | 1/2/3 |
Accuracy | C1 | C2 | C3 | |
Maximum number of verification intervals | n max | 1000 | 2000 | 3000 |
Minimum load cell verification interval | v min | Emax/3000 | Emax/5000 | Emax/7500 |
Combined error | (%FS) | ≤±0.050 | ≤±0.030 | ≤±0.020 |
Creep | (%FS/30min) | ≤±0.038 | ≤±0.023 | ≤±0.016 |
Temperature effect on sensitivity | (%FS/10ºC) | ≤±0.028 | ≤±0.017 | ≤±0.011 |
Temperature effect on zero | (%FS/10ºC) | ≤±0.047 | ≤±0.029 | ≤±0.019 |
Output sensitivity | (mv/v) | 2.0±0.01 | ||
Input resistance | (Ω) | 770±30 | ||
Output resistance | (Ω) | 700±5 | ||
Insulation resistance | (MΩ) | ≥5000(50VDC) | ||
Zero balance | (%FS) | 1.5 | ||
Temperature,compensated | (ºC) | -10~+40 | ||
Temperature,operating | (ºC) | -35~+65 | ||
Excitation,Recommended | (V) | 5~12(DC) | ||
Excitation,Max | (V) | 18(DC) | ||
Safe overload | (%FS) | 150 | ||
Ultimate overload | (%FS) | 300 |
Prod Model: | H2F |
---|---|
Markets: | North America,South America,Eastern Europe,Southeast Asia,Africa,Oceania,Mid East,Eastern Asia,Western Europe |