Product Specifications
| Prod Model: |
SHDN-160 |
| Markets: |
North America,South America,Eastern Europe,Southeast Asia,Africa,Oceania,Mid East,Eastern Asia,Western Europe |
| Size: |
0.5 to 15 Square Meter |
| Power Line: |
Black, 2,3,4m |
| Heat Source: |
Heat & Power Plant |
| Type: |
Heating Mat |
| System Structure: |
Heating Wire and Mat |
| Heat Medium: |
Conduct |
| Material: |
Copper Nickel Alloy Wire |
Product Description
Underfloor Heating Mat
Senphus Underfloor Heating Mats are the easiest and fastest to install, and are best suited for rectangular-shaped areas. The cable is pre-spaced on the mesh at 9cm, offering optimal heat distribution.
Underfloor heating mat Specification
| SH PCN | Type | Rated power | Resistance | Mat size | Length |
| W | Ω | m | m |
| SHDN00075 | SHDN-160-1.0M2 | 160 | 302.5 | 0.5X2.0 | 11.1 |
| SHDN00076 | SHDN-160-1.5M2 | 240 | 201.7 | 0.5X3.0 | 16.65 |
| SHDN00077 | SHDN-160-2.0M2 | 320 | 151.3 | 0.5X4.0 | 22.2 |
| SHDN00078 | SHDN-160-2.5M2 | 400 | 121 | 0.5X5.0 | 27.75 |
| SHDN00079 | SHDN-160-3.0M2 | 480 | 100.8 | 0.5X6.0 | 33.3 |
| SHDN00080 | SHDN-160-3.5M2 | 560 | 86.4 | 0.5X7.0 | 38.85 |
| SHDN00081 | SHDN-160-4.0M2 | 640 | 75.6 | 0.5X8.0 | 44.4 |
| SHDN00082 | SHDN-160-4.5M2 | 720 | 67.2 | 0.5X9.0 | 49.95 |
| SHDN00083 | SHDN-160-5.0M2 | 800 | 60.5 | 0.5X10.0 | 55.5 |
| SHDN00084 | SHDN-160-6.0M2 | 960 | 50.4 | 0.5X12.0 | 66.6 |
| SHDN00085 | SHDN-160-7.0M2 | 1120 | 43.2 | 0.5X14.0 | 77.7 |
| SHDN00086 | SHDN-160-8.0M2 | 1280 | 37.8 | 0.5X16.0 | 88.8 |
| SHDN00087 | SHDN-160-9.0M2 | 1440 | 33.6 | 0.5X18.0 | 99.9 |
| SHDN00088 | SHDN-160-10.0M2 | 1600 | 30.3 | 0.5X20.0 | 111 |
| SHDN00099 | SHDN-160-12.0M2 | 1920 | 25.2 | 0.5X24.0 | 133.2 |
Underfloor Heating Mats Installation Guide
1.The insulation board must be installed if you have a wooden substrate. It is also recommended with concrete substrates to optimise efficiency and reduce warming times(up to 50% more thermally efficient).
2.Always round down your floor space area e.g. 2.6m2 of floor will require 2 m2 of matting (To avoid surplus matting).
3.Neververlap the mat, always ensure a min.50mm spacing between the wires for optimum heat distribution.
4.If there is a matting shortfall in your floor space then concentrate the heat mat in heavily trafficked areas.
5.A Residual Current Device(RCD) should be used with this system(must be bought separately).
6.Floor must be clean and free from dust & dirt.
7.Never cut the heating(red or blue color) wire or join two or more mats together in series, use a junction box.
8.Only use scissors when cutting the mesh.
9.The wire is tough but extra care must be taken when using sharp objects near the mat. a plastic trowel is advisable.
10.Check your system with a multi-meter before tile installation.
11.Ensure your tile adhesive is suitable for use with undertile heating e.g. highly polymer modified(flexible).
12.Your substrate and floor covering, e.g. tile adhesive or screed, must be completely dry before switching on your system for the first time.
13.Wear gloves when handling the mat(to avoid irritation to skin).
14.Take care when tiling to ensure your do not dislodge or damage the wire from the mesh mat.
15.The insulation board is not suitable for floor strengthening and structural reinforcing.
16.Matting and insulation board should not be passed under permanent fixings e.g. bath, toilet, etc.
17.Do not store objects on top of the matting during installation e.g. tiles.
Jiangyin Senphus Electrical Material Co., Ltd is a new Hi-tech enterprise of heating alloy, heating cable/mat, heating wire, silicone rubber heater, drum silicone rubber heater, thermostat, which is engaging in R&D, manufacture and sale.
We have our own alloy smelting factory, possessing first-class production and advanced research facilities, so that we guarantee the top quality of our products. We have already passed ISO9001 quality management system and achieved the examination report of National Center for quality Supervision & Test of Electric Wire & Cable, and gained the European Union CE certification, UL certificate, GS Certificate, electromagnetic radiation certification, SGS and REACH certification.
Heating cable/wire and temperature controller system are widely used in wind power blades, construction heating, pipeline heating, outdoor snow melting, soil heating field and so on. Silicone rubber heater are widely used in electrical household appliance, spaceflight, petroleum, metallurgy, military project, chemical, electric power, medical appliance, mechanism, outdoor communication, automobile, etc. Industry.
Our products have been exported to America and Europe, Africa, Southeast Asia, like USA, Canada, England, France, Holand, Poland, Peru, South Africa, Italy, Greece, Thailand, India, Hongkong, etc. More than thirty countries and areas.
Our company always persist in"reputation first, quality high and customers supreme" management ideal. We will use great products, competitive price, professional service to cooperate with you and gain win-win!
OEM is welcome! !