Shanghai Lemore Trade Co., Ltd. >> WPC-10 Series Pressure Controller

WPC-10 Series Pressure Controller

WPC-10 Series Pressure Controller
Supplier: Shanghai Lemore Trade Co., Ltd.
Price: US $ 20/Piece
Min Order: 10/Piece
Quantity::
Trade Terms: FOB,CFR
contact supplier

Product Specifications

Prod Model: WPC-10
Markets: North America,South America,Eastern Europe,Southeast Asia,Africa,Oceania,Mid East,Eastern Asia,Western Europe

Product Description

Environment-friendly:silent design.
Safe: IP65,water-proof case,water-shortage protection.
Intelligent: Preventing the pump automatically restart frequently.
Reliable: Electronic Design, long-life for using, more than 200,000 times operation,anti-vibration.
Widely application:Pipeline Pump,Booster Pump,Self-priming pump,Immersible Pump,Circulating Pump ect.,widely using for solar heat pump,air-source heat pump,WILO home booster pump,hot water circulating pump and other relevant pumps.


WPC-10 Electronic Pressure Controller for Pump which is a digital display pressure switch .WPC-10 integrated the function of measure,display and control. It is easy for operation,anti-vibration,high accuracy,long-life for using. The extra function like water shortage protection,error correction and password protected. It can control and protect your pump very well.

The Wiring
Please see the back of the WPC-10 pressure control,the left is Chinese word"",you can supply 220Vac from here,the right is Chinese word"",please connect it with the pump 220Vac supply terminal.

Notice
1. Please set the correct upper and lower pressure value and water shortage protection value before using our device.
2. Please cut off the power when you install our device.
3. Please don't immerse the device into the water.
4. Please read the manual carefully before using.
5. Please don't repair the device privately,or it regard as you give up the warranty.
6. One-year warranty, free service for repair but buyer bear the freight cost of return.

Setting
1. Set ON/OFF Pressure value:
Default: Start @ 1.5KG/CM2 (lower); Stop @ 2.9KG/CM2(upper)
(1) Press "on/off" key to start the setting (1 SECOND)
CHANGE THE UPPER VALUE
(2) Press key ,it display:"H2.9",then you pressure the again(1 SEC.),the value will be added by 0.1KG,you can also long press the key to speed it and set your upper value.After setting.please wait 2 sec.,the device will display"888" ,it will be save your setting value automatically.
Remark: The Upper Limited :"Lower value ~9.9", LOOP SETTING
CHANGE THE LOWER VALUE
(3) Press key ,it display:"L1.5",then you pressure the again(1 SEC.),the value will be reduced by 0.1KG,you can also long press the key to speed it and set your lower value.After setting.please wait 2 sec.,the device display"888",it will be save your setting value automatically.
Remark: The Lower Limited :"water shortage protection value ~the upper limit value", LOOP SETTING
(4) After Setting,you can start use the WPC-10 pressure controller.

2. How to SET the value of water shortage protection value?
(1) Press "on/off" key to start the setting (1 SECOND)
(2) Press the "Protect",the default value"F0.2",setting method which is the same with upper and lower value setting.
Remark:Protection Value Rang"0.1~the lower value",but you can set it according to your actual usage.Reference"0.1~0.5"
(3) Cancel the water shortage protection,you set the value "F0.0"

3. Reset and Error Correction
(1) Press "on/off" key to start the setting (1 SECOND)
(2) Press ""+"ON/OFF" 5 seconds,you will see "C-L",the device reset successfully.
Remark:You must set it without any pressure.If the device does n't display 0.0 when you use it in the first time,please reset it before using.

4.Time-delay for Stop the Pump
In order to prevent the pump start and stop frequently,we can set a time-delay for stop the pump. Please press "protect"+"",it display"n03"(default time delay 3 seconds),then you can press up or down key to modify the value,then press the "ON/OFF"key to save the setting.
Technical Parameter
Pressure Range 0-10KG f/CM
Voltage Supply 220Vac(You require a 3 phase AC contactor with 380V pump)
Connection G1/2(Standard),it also can be customized
Overload Capacity 220V,10A; Pump(≤1.5KW) can be started directly
 
 
Read The Code
Code Meaning How To Use
H2.9 Upper value,stop@2.9KG You can set it as instruction
L1.5 Lower Value,stop@1.5KG You can set it as instruction
F0.2 Water shortage protection  @0.2KG You can set it as instruction
E-F Water shortage protection Press ON/OFF to restart or waiting for restart automatically                                                                     
E-H Error,over the pressure range Check the pressure source
The Shanghai Lemore Trading Co., Ltd. was founded in 2008, which is known as a professional pressure sensor and temperature control solution expert over global market, .
Shanghai Lemore invested in 5 standard factories which in dealing various electric appliances such as water pump pressure control, general application pressure sensor and temperature datalogger and other relevant products, Due to the Industry develpment and spare parts inner support. That's make sure our customers can get competitive price, reliable quality and good sevice from us.
Why choose us?
Client-orientated_let customers feel valuable to work with us
You can get professional technology support, enjoy absorbed service attitude, feel like you are the VIP customer.
Speed_reply your email within 24 hours
Flexibility_accept OEM and small trial orders, even can supply products with your target price
Further more, we always focus on new products in Chinese market.
Consistency_from the first contact to the after sell service with fixed sales team.
Professional_have related engineers, active sales team, offer competitive price in reliable quality
international standards such as CE, UL, FCC, IEC, KEMA, SEMKO, FIMKO, ESC, RoHS, VDE, CB

Send your message to this manufacturer

  • Inquiry about WPC-10 Series Pressure Controller

Other Products From This Manufacturer