Ambient Condition
1 Ambient air temperature: -5°~ +40°C
2 Average temperature not more than +35°C wihin 24 hours;
3 Indoor installation
4 use site shall not exceed 2000M;
5 air relative humidity:maximum temperature +40°C at most 50%. Allowed major relative humidity at cryogenic temperature;
6 Equipment installation with vertical slope not more than 5%;
7 There is no risk of fire hazard and explosion, non conductive dust, corrosive gas and strong vibration.
8 Any specific requirements, please consult with manufacturer for compromise settlement
GCS series low voltage withdrawable type switch cabinet (short for "cabinet") is developed by united professional designers according to the requirements of related business departments,electric power users and design organizations. With high technical performance index, it can meet the demands of electric power marketing development, and compete with existing products. The equipment has currently been widely used in different places.
The cabinet is mainly applied in distribution system of power stations, oil industries, chemical industries, metallurgy industries, textile industries, and high-rise buildings. It also works in places, such as big power stations and petrochemical system requested by high degree automaticity and contacting with computers, as low-voltage power distribution unit in the system of three-phase ac frequency 50 (60)HZ,rated voltage 380 (400),V (660) V, rated current ≤5000A, to distribute and control electric power.
Design requirements meet the following standard : IEC439-1 Low voltage complete switch and control equipment, GB7151.1-2005 Low voltage complete switch equipment
Rated voltage of main circuit (V) | | 380(400),(600) |
Rated voltage of auxiliary circuit (V) | AC | 220,380(400) |
DC | 110,220 |
Rated frequency (Hz) | | 50(60) |
Rated insulation voltage (V) | | 660(1000) |
Rated curren (A) | Horizontal bus-bar | | <=4000A |
Vertical bus-bar (MCC) | | 1000A |
Rated short-time withstand current of bus-bar (KA/S) | | 50,80 |
Peak bus-bar durable consumer goods current (KA/0.1S) | | 105,176 |
Power frequency test voltage (V/1MIN) | Main circuit | 2500 |
Auxiliary circuit | 2000 |
Bus-bar | Three-phase four-wire system | A.B.C.PEN |
Three-phase five-wire system | A.B.C.PEN |
Our company supplys different kinds of products. High quality and favaroble price. We're pleased to get your Inquiry and we will come back to as soon as possible. We stick to the principle of "quality first, service first, continuous improvement and innovation to meet the customers" for the management and "zero defect, zero complaints" as the quality objective.