Product Specifications

Prod Model: DW17
Markets: North America,South America,Eastern Europe,Southeast Asia,Africa,Oceania,Mid East,Eastern Asia,Western Europe
Type: Circuit Breaker
Function: Over Load and Short Circuit Protection
Arc-extinguishing Medium: Air
Breaking Capacity: Low Voltage Circuit Breakers
Operation: Electric Type
Installation: Fixed
Speed: High-Speed Circuit Breaker
Structure: Frame-Type

Product Description

DW17
Application
1. DW17 series universal circuit breaker (Abbr circuit breaker) feature in compact conformation and size, light weight, featured series, good components interchangeability, perfect protection system, high technical economy standard, convenient maintenance and usage. The technical performance of circuit breaker conforms to IEC947-2 and GB14048.2-94. Standards. The circuit breaker is applicable to rated working voltage and current with 380V, 660V, 50Hz, which is mainly used for power distribution and infrequent changing over; And protection for the overload, under voltage and short circuit of circuit and electric equipment, also with the protection of classified choice. It can actuate the motor directly and protect the motor, generator and rectifier from the damage of overload, short circuit and under voltage, etc.
2. The typic connection types of circuit breaker. ( refer to diagram 1)
3. The classification and specification of circuit breaker (refer to table 1) NOTE: 1, Overload long-time delay release with fastener W1 or with fastener and signal W2, short circuit instantaneous release with fastener W3 or with fastener and signal W4; W1, W2, W3, W4 is just used for frame level 1, 2 and 3. And short circuit release is used for all series. If need, it can be indicated when ordering.
Electric operation is enclosed maintenance operation manual; Drawout type circuit breaker is enclosed the operation manual of position alteration and the expansion guidways of maintenance. The customer can order according to his need.
Blocking solenoid is mainly used for the protection of circuit breaker of motor.
2. Normal working condition
2.1 Ambient air temperature
2.1. 1 The highest ambient air temperature is less than +40 oC
2.1. 2 Ambient air temperature is less than +35 oC with 24h average value.
2.1. 3 The lower value of ambient air temperature is not less than -5oC.
2.2 Altitude of installating site not exceeding 2000 meters above sea level.
2.3 Atmospheric condition:
Relative humidity not higher than 50% at ambient temperature of +40 oC. Higher relative humidity permissive at lower temperature; Max relative humidity of monthly average 90% in the wettest month, temperature of monthly temperature +25oC allowing for condensed dew produced due to temperature fluctuations.
2.4 Pollution classification: Pollution classification three
2.5 Installation condition: The breaker should be completely installed or separately installed indoors with inclination with vertical plane not greater than 5 degree.
3 technical parameters and performances

NO ModelThree poleFour poleComments
NO   Model Three pole Four pole Comments
Classification DW17-1900 DW17-2900 DW17-3900 DW17-1900
630 800 1000 1250 1600 1900 2000 2500 2900 3200 3900 630 800 1000 1250 1600
1 Operating mode AC Up to 660V Any one is selectable
DC Up to 440V
2 Operating mode Manually Directly operated on right side     Any one is selectable
Directly operated on the front    
Quickly operated on the front
Motor driven Motor operated vv
Motor pre-changed operation with v v v
3 Voltge trip Under voltage trip Instantaneous operation It can be choosed for two types during three trippers of double shunt tripper
Time delay operation
Shunt trip
Blocking solenoid          
4 Over current trip Long time delay operation for overload and intantaneous operation for short circuit     Any one is selectable
Long time delay operation for overload and time delay operation for short circuit    
Instantaneous operation for short circuit
Short-time delay operation for short circuit(Zz)
Without overcurrent trip
5 Installation and wiring Fixed type Vertical connection Any one is selectable
Horizontal connection    
Plugged type Horizontal connection
Vertical connection v
   
Constructional dimension class of the breaker Type of breaker Rated current at IPOO
Fixed type Drawout
35 o C 45 o C 55 o C 35 o C 45 o C 55 o C
Constructional dimension 1 DW17-630 630 630 630 630 630 630
DW17-800 800 800 800 800 800 800
DW17-1000 1000 1000 1000 1000 1000 1000
DW17-1250 1250 1250 1250 1250 1250 1250
DW17-1600 1600 1530 1460 1600 1530 1460
DW17-1900 1900 1810 1720 1900 1720 1620
Constructional dimension 2 DW17-2000 2000 2000 2000 2000 2000 2000
DW17-2500 2500 2500 2500 2500 2400 2300
DW17-2900 2900 2900 2900 2900 2900 2770
constructional dimension 3 DW17-3200 3200 3200 3200 3200 3200 3200
DW17-3900 3900 3900 3900 3900 3900 3750
Yueqing Eidell Electric Technology Co., Ltd., located in Liushi, yueqing city and known as the city of electrical, is professional in developing, manufacturing and marketing of Miniature circuit breaker (MCB), Residual current circuit breaker (RCCB, RCBO), Moulded case circuit breaker (MCCB), Terminal Block, Voltage Stabilizer and other low voltage electric accessories. Our products are exported to more than 10 countries and regions such as South America, Western Europe, the Middle East, Africa, etc.

We take "Honesty, Modesty, Innovation Win-Win as our management philosophy, always take the customer as the center, and spare no effort to provide the customer with safe and reliable electrical products with high quality and reasonable price. We also provide OEM and ODM services. Warmly welcome old and new customers at home and abroad to visit our company and negotiate business.