Product Specifications
Markets: |
North America,South America,Eastern Europe,Southeast Asia,Africa,Oceania,Mid East,Eastern Asia,Western Europe |
Product Description
1. General
SRE6 SF6 Gas Insulated Switchgear (RMU) is a new type of SF6 GIS of medium-voltage ring modularized extensible switchgear, Safe-ring-extend-SF6, abbreviated as SRE6.
All SRE6 SF6 Gas Insulated Switchgear are in accordance with the requirements of IEC 60298 and GB 12706 and pass the type tests specified by the Xi'an High Voltage Apparatus Research Institute. Their service lives exceed 20 years.
2. Main characteristic
Safe, reliable and stable
?Safety: 3-position load switch may be interlocked, switch positions are indicated legibly; in the case of standard configuration, the function of voltage presence indication is possessed to ensure safety. Reliable gas duct and the design of arc fault prevention, passing the 20 kA internal arcing type test.
?Stability: Programmingdesign, normalized process control, and modular combination ensure stable quality.
All insulation, full enclosure, free maintenance
?All high-voltage live parts are fully enclosed in the SF6 Gas Insulated Switchgear, and the degree of protection is up to IP67. The whole switchgear is free from external environmental impact, which realizes all insulation, full enclosure, and maintenance free.
Arbitrary assembling, unrestricted extensibility
?A split box type is used, or an integrated box of multiplex unit may also be realized. Free assembling of all modular units meets the requirement of different customers. Unit modules may be extensible in situ flexibly, and a variety of MV substations may be constructed for different requirements. Modular design, freely extensible combination.
4,Intelligent integration
?An intelligent distribution network system is provided for realization of self-contained protection, remote control, monitoring, fault handling, etc. Integrated installation and debugging in the plant; minimizes the field work load.
Technical Data
Item | Unit | Data |
Rated voltage | kV | 11/12 |
Rated insulation voltage | 1 min power frequency withstand voltage | kV | 42 |
Lightning impulse withstand voltage(peak) | kV | 75 |
Rated frequency | Hz | 50 |
Rated current | A | 630 |
Rated short-time withstand current | kA | 20 |
Rate peak withstand current | 50 |
Rate short-circuit duration | S | 4 |
a.c. component of rate short-circuit breaking current | kA | 20 |
Rated short-circuit making current | kA | 20 |
Mechanical life | time | 10000 |
|
Suzhou Silverstone Electric Specialises in Power Transmission, Distribution, Electrical Automation Solutions, Power Quality Solutions, Hydro Power, Solar Power, Power Generation and Substation EPC Consultant.
We manufactures and trades
Power Transformer
--Dry type Transformer (up to 35kV)
--Oil Immersed Transformer (up to 230kV)
GIS (Gas Isolated Switchgear)
--Up to 145kV Compact Gas Insulated Switchgear (GIS)
--Up to 230kV Gas Insulated Switchgear (GIS)
MV Switchgear
--Metal clad AC Enclosed Switchgear
--Packaged Type AC Metal Enclosed Switchgear
--Gas Insulated Switchgear
LV Switchgear
--LV Withdrawable Switchgear
--LV Fixed Switchgear
MV Circuit Breaker
--Vacuum Circuit Breaker
--SF6 Circuit Breaker
--MV Earthing Switch
--Load Break Switch
Reactor
--Dry-type Air Core Reactor Series
--Dry-type Core Series Shunt Reactor
--HV Oil-immersed Shunt Reactor
HV&LV Busbar Trunking System
--Busbar Trunking System (Busway)
--Common Enclosure Busbar
HV Circuit Breaker & Disconnector
--HV Circuit Breaker
--SF6 Circuit Breaker
--HV Disconnector
--Outdoor AC discontector
--HV Earthing Switch
--Outdoor AC Earthing Switch
Capacitor
--All film high voltage shunt capacitor
--High-voltage shunt capacitor banks
--Atlernating filter capacitor complete equipments
Power Protection & Automation
Reactive Compensation
High Voltage Frequency Reactor
Medium voltage variable frequency drives
Medium voltage soft starter
STATCOM (Static synchronous compensator)
Static var compensator with Magnetically controlled reactor
TSC (Thyristor switched capacitor banks)
Active power filter