Product Specifications
| Markets: |
North America,South America,Eastern Europe,Southeast Asia,Africa,Oceania,Mid East,Eastern Asia,Western Europe |
| Size: |
Miniature |
| Theory: |
Electromagnetic Relay |
| Usage: |
Household Appliances Relay, Communication Relay |
| Protective Characteristics: |
Open Relay |
| Load: |
Medium Power Relay |
| Action Principle: |
Electromagnetic Type |
Product Description
1.Application
CJX2 series AC Contactor is suitable for using in the circuits up to the rated voltage 660V AC50Hz or 60Hz, rated current up to 620A, for making, breaking, frequently starting & controllingthe AC motor. Combined with the auxiliary contact block, timer delay & machine-interlockingdevice etc, it becomes the delay contactor, mechanical interlocking contactor, star-delta starter.With the thermal relay, it is combined into the electromagnetic starter. The product conforms toIEC60947-4-1 stardand.
2. Specification
| Type | CJX2-D09 | CJX2-D12 | CJX2-D18 | CJX2-D25 | CJX2-D32 | CJX2-D40 | CJX2-D50 | CJX2-D65 | CJX2-D80 | CJX2-D95 |
| Rated workingcurrent (A) | AC3 | 9 | 12 | 18 | 25 | 32 | 40 | 50 | 65 | 80 | 95 |
| AC4 | 3.5 | 5 | 7.7 | 8.5 | 12 | 18.5 | 24 | 28 | 37 | 44 |
| Standardpower ratingsof 3-phasemotors50/60Hz incategory AC-3 | 220/230V | 2.2 | 3 | 4 | 5.5 | 7.5 | 11 | 15 | 18.5 | 22 | 25 |
| 380/400V | 4 | 5.5 | 7.5 | 11 | 15 | 18.5 | 22 | 30 | 37 | 45 |
| 415V | 4 | 5.5 | 9 | 11 | 15 | 22 | 25 | 37 | 45 | 45 |
| 500V | 5.5 | 7.5 | 10 | 15 | 18.5 | 22 | 30 | 37 | 55 | 55 |
| 660/690V | 5.5 | 7.5 | 10 | 15 | 18.5 | 30 | 33 | 37 | 45 | 55 |
| Rated heat current (A) | 20 | 20 | 32 | 40 | 50 | 60 | 80 | 80 | 125 | 125 |
| Electrical life | AC3 (x104) | 100 | 100 | 100 | 100 | 80 | 80 | 60 | 60 | 60 | 60 |
| AC4 (x104) | 20 | 20 | 20 | 20 | 20 | 15 | 15 | 15 | 10 | 10 |
| Mechanical life (x104) | 1000 | 1000 | 1000 | 1000 | 800 | 800 | 800 | 800 | 600 | 600 |
| Number of the contacts | 3P+NO | 3P+NC+NO |
| 3P+NC |
| Type | CJX2-D115 | CJX2-D150 | CJX2-D170 | CJX2-D205 | CJX2-D245 | CJX2-D300 | CJX2-D410 | CJX2-D475 | CJX2-D620 |
| Rated workingcurrent (A) | AC3 | 115 | 150 | 170 | 205 | 245 | 300 | 410 | 475 | 620 |
| | AC4 | 52 | 60 | 75 | 85 | 105 | 117 | 138 | 147 | 180 |
| Standard powerratings of 3-phase motors50/60Hz incategory AC-3 | 220/230V | 30 | 40 | 55 | 63 | 75 | 100 | 110 | 147 | 200 |
| 380/400V | 55 | 75 | 90 | 110 | 132 | 160 | 220 | 265 | 335 |
| 415V | 59 | 80 | 100 | 110 | 132 | 180 | 220 | 280 | 375 |
| 500V | 75 | 90 | 110 | 129 | 160 | 200 | 250 | 355 | 400 |
| 660/690V | 80 | 100 | 110 | 129 | 160 | 220 | 280 | 355 | 450 |
| Rated heat current (A) | 200 | 250 | 250 | 275 | 315 | 400 | 500 | 700 | 1000 |
| Electrical life | AC3 (x104) | 200 | 60 | 60 | 50 | 50 | 50 | 30 | 30 | 20 |
| AC4 (x104) | 15 | 15 | 15 | 15 | 15 | 15 | 8 | 8 | 5 |
| Mechanical life (x104) | 300 | 300 | 300 | 300 | 300 | 300 | 300 | 100 | 100 | 100 |
3. Standard Control Circuit Voltage
| Volts | 24 | 42 | 48 | 110 | 220 | 230 | 240 | 380 | 400 | 415 | 440 | 500 | 600 |
| 50Hz | B5 | D5 | E5 | F5 | M5 | P5 | U5 | Q5 | V5 | N5 | R5 | S5 | Y5 |
| 60Hz | B6 | D6 | E6 | F6 | M6 | - | U6 | Q6 | - | - | R6 | - | - |
| 50/60Hz | B7 | D7 | E7 | F7 | M7 | P7 | U7 | Q7 | V7 | N7 | R7 | - | - |
4. Outline and Mounting Dimension
| Type | A | B | C | D | E | a | b | Φ |
| CJX2-D09~12 | 47 | 76 | 82 | 113 | 133 | 34/35 | 50/60 | 4.5 |
| CJX2-D18 | 47 | 76 | 87 | 118 | 138 | 34/35 | 50/60 | 4.5 |
| CJX2-D25 | 57 | 86 | 95 | 126 | 146 | 40 | 48 | 4.5 |
| CJX2-D32 | 57 | 86 | 100 | 131 | 151 | 40 | 48 | 4.5 |
| CJX2-D40~65 | 77 | 129 | 116 | 145 | 165 | 40 | 100/110 | 6.5 |
| CJX2-D80~95 | 87 | 129 | 127 | 175 | 195 | 40 | 100/110 | 6.5 |
| Type | A | B | C | b1 | P | Q | S | Q1 | M | N | L | Φ | Ga | Ha |
| CJX2-D115 | 158 | 120 | 132 | 158 | 35 | 60 | 17 | 25 | 134 | 96.2 | 75 | M6 | - | - |
| CJX2-D150 | 158 | 120 | 132 | 158 | 35 | 60 | 17 | 25 | 134 | 96.2 | 75 | M6 | - | - |
| CJX2-D170 | 158 | 120 | 132 | 158 | 35 | 60 | 17 | 25 | 134 | 96.2 | 75 | M6 | - | - |
| CJX2-D205 | 168.5 | 174 | 181 | 137 | 40 | 69 | 20 | 59.4 | 154 | 127 | 113.5 | M8 | 80 | 120-106 |
| CJX2-D245 | 168.5 | 197 | 181 | 137 | 48 | 69 | 25 | 51.5 | 172 | 127 | 113.5 | M10 | 80 | 120-106 |
| CJX2-D300 | 213 | 206 | 219 | 145 | 48 | 91 | 25 | 74 | 181 | 158 | 145 | M10 | 80 | 120-106 |
| CJX2-D410 | 213 | 206 | 219 | 209 | 48 | 91 | 25 | 74 | 181 | 158 | 145 | M10 | 80 | 120-106 |
| CJX2-D475 | 233 | 238 | 232 | 209 | 55 | 108 | 30 | 77 | 208 | 172 | 146 | M10 | 80 | 180 |
| CJX2-D620 | 309 | 304 | 255 | 280 | 80 | 140 | 40 | 89 | 264 | 202 | 155 | M12 | 80 | 180 |
5. Auxiliary contact block
| Appellation | Type |
Auxiliary instantaneous contactor block,contactor I | LA1-DN10C |
| LA1-DN01C |
| Appellation | Type |
Auxiliary instantaneous contactor block,contactor II | LA1-DN11C |
| LA1-DN20C |
| LA1-DN02C |
| Appellation | Type |
Auxiliary instantaneous contactor block,contactor IV | LA1-DN40C |
| LA1-DN31C |
| LA1-DN22C |
| LA1-DN13C |
| LA1-DN04C |
| Appellation | Type |
Auxiliary instantaneous contactor block,contactor IV | LA1-DN40C |
| LA1-DN31C |
| LA1-DN22C |
| LA1-DN13C |
| LA1-DN04C |
| Appellation | Type |
| Side-mounted auxiliary module | LA8-DN11C |
| LA8-DN20C |
6. LA2 time delay auxiliary contact block
| Appellation | Type |
| Auxiliary instantaneouscontactor block,contactor IV | 0.1...3S LA2-DT0 |
| 0.1...30S LA2-DT2 |
| 10...180S LA2-DT4 |
| 1...30S LA2-DS2 |
| Appellation | Type |
| Time delay auxiliary contactorblock releasing and delay | 0.1...3S LA2-DT0 |
| 0.1...30S LA3-DT2 |
| 10...180S LA3-DT4 |
![]()
Elecal Industrial Automation is Specializing in the manufacture and export of low-voltage and hight-voltage electrical products in China. Such as MCB, MCCB, ELCB, RCD, Contactor, Fuse, Relay, Switch, Distribution Box etc.
All the manufacturing process of the products is in strictly conformity to international IEC standard and we have established and perfected quality control procedures in accordance with ISO9001 international quality management system.